Kamis, 28 Juli 2016

Eternity Anesthesia Machine AM852


Anesthesia machine AM852
Features:
1. Advanced anesthesia machine with high technology,support a variety of patients;
2. Suitable for neonate, pediatric & adult;
3. Meet low flow requirement by multi parameter monitoring;
4. Electronic flowmeter of high accuracy and intuitive displaying;
5. Integrated high temperature sterilization CO2 absorber system,excellent ergonomic breathing circuit,with heating and bypass function;
6. Safe & reliable gas system
7. CE marked, meet EU clinical requirement

Product details
Technical Specification
  Physical & Environmental Specification
. Dimensions (WxHxD): 600x1368x740mm
. Weight: 130kg
. Storage temperature:  -10~+60
. Working temperature:  +10~+40
. Storage humidity: 15%~90%

  Electrical Specification
. Mains: 100-240VA C, 50-60Hz
. Battery: 24VDC, minimum120min 

  Pneumatic Specification
. Gas supply: AIR, O2, N2O: 0.28-0.6Mpa
. Flowmeters:  Electronic flowmeter
.Gas supply:   O2 deficiency alarm
 .Hypoxic guard system
. O2flush: 25-75L/min
. Working mode: Closed, Semi-closed, Semi-open
. Driven mode: Pneumatically driven and electronically controlled
. Operating mode: Man. / Vent.

  Ventilator Specification
. Patient type: Adult, pediatric & neonate
. Ventilation modes: VCV,PSV,PCV,SIMV,Standby, Manual
. Setting: Touch key & navigator wheel knob&touch screen
. Tidal volume: 20-1500ml
. Ventilation frequency: 0-100bmp
. I:E ratio: 10:1-1:10
. Pressure control: 5-70cmH2O
. Ppeep: 0-40cmH2O
. Inspiratory plateau: off, 0-60%Ti
. Trigger sensitivity: Flow and pressure trigger
. High pressure: 20-100cmH2O
. Low pressure: 0-20cmH2O
. Monitoring: Display: 12TFT color touch screen
            Pressure: Paw, Ppeak, Pplat, Pmean
            Volume: MV, Vt
            Flowmeter
            Vaporizer agent
            Breath rate
            Gas: FiO2
            Compliance
            Graph display: P-T, F-T, V-T waveforms & P-V, F-V loops. Waveform frozen
. Alarm: Pressure: Paw, high/low limit
              Volumes: TV/MV high/low limit
              High limit of breath rate
             Gas: FiO2 high/low limit
            Apnea
            Airway pressure high
            High PEEP level
            Power failure
            Battery low
            Low O2 supply pressure

Vaporizer
. Support 2 vaporizer (Selectatec compatible)
. Agent type: Halothane, Enflurane, Isoflurane, Sevoflulrane available.

Optional
EtCO2&SpO2 module
AGSS
Anesthetic gas module

Tidak ada komentar: